INTERLAN AT installation sample files for the NDIS driver for the 
following applications:

     - PC/TCP
     - PCNFS Ver 3.5
     - AS400 PC support
     - Banyan 
     - Pathworks 
     - Lan Manager


*********************************************************************
*** PC/TCP v2.05 and v2.11 Installation for INTERLAN AT with NDIS ***
*********************************************************************

1a.    Install PC/TCP Version 2.05 beginning with the diskette
       labelled "Workstation Distribution #1".

1b.    Install PC/TCP Version 2.11 beginning with the diskette
       labelled "Regular Distribution #1". When prompt for DISK #2 
       insert diskette labelled "Workstation Distribution #2".

2.     Once the above installation is completed, update the
       config.sys, autoexec.bat, and protocol.ini files to reflect
       the samples provided.
3.     Copy the proper files into the \pctcp\ndis subdirectory 
       as per samples below.
4.     Install the INTERLAN AT and you should be up & running when the PC
       boots up.



Config.sys                                                
----------
files = 50                                           
buffers = 10                                                       
device = c:\dos\ansi.sys                                    
device = c:\pctcp\protman.sys /i:c:\pctcp\ndis (path to protocol.ini)                      
device = c:\pctcp\ndis\ILANAT.DOS                                        
device = c:\pctcp\dis_pkt.gup                                
device = c:\pctcp\ifcust.sys    (not needed for v2.11)                                           
device = c:\pctcp\ipcust.sys    (not needed for v2.11)                                           

                                                    
Autoexec.bat                                        
------------
echo off                                                  
prompt $p$g                                                      
set pctcp=c:\pctcp\pctcp.ini    (needed for v2.11)
set path=c:\pctcp;%path%        (needed for v2.11)
path=c:\;c:\dos;c:\pctcp;                                 
c:\pctcp\netbind
c:\pctcp\ethdrv


Protocol.ini
------------
[PROTOCOL MANAGER]
      Drivername    = Protman$

[ILANAT_NIF]
      Drivername    = ILANAT$
      Iobase        = 0x300
      Maxtransmits  = 6
      Maxreceives   = 4
      Maxmulticasts = 10

[PKTDRV]
      Drivername = pktdrv$
      Bindings   = ILANAT_NIF
      intvec     = 0x65
      chainvec   = 0x66



***********************************************
*** PCNFS Ver 3.5 for INTERLAN AT with NDIS ***
***********************************************

Config.sys
----------
files = 50
buffers = 20
device = c:\nfs\pcnfs.sys /r4 /f40 /s /y
device = c:\nfs\sockdrv.sys
device = c:\lanman\protman.sys /i:c:\lanman (path to protocol.ini)
device = c:\lanman\ILANAT.DOS
device = c:\lanman\nfs-ndis.sys


Protocol.ini
------------
[PROTOCOL MANAGER]
      Drivername = Protman$

[ILANAT_NIF]
      Drivername    = ILANAT$
      Iobase        = 0x300
      Maxtransmits  = 6
      Maxreceives   = 4
      Maxmulticasts = 10

[NFS-NDIS]
      Drivername = NFSlink1
      Bindings   = ILANAT_NIF



**************************************************
*** AS400 PC Support for INTERLAN AT with NDIS ***
**************************************************

CONFIG.SYS
----------
files = 50
buffers = 20
device = \dos\ansi.sys
lastdrive = f
device = c:\as400\protman.sys /I:C:\as400 (path to protocol.ini)
device = c:\as400\ILANAT.DOS
device = c:\as400\dxma0mod.sys 001
device = c:\as400\dxme0mod.sys


PROTOCOL.INI
------------
[PROTOCOL MANAGER]
      Drivername = Protman$

[ILANAT_NIF]
      Drivername    = ILANAT$
      Iobase        = 0x300
      Maxtransmits  = 6
      Maxreceives   = 4
      Maxmulticasts = 10

[ETHERAND]
      Drivername = DXME0$
      Bindings   = ILANAT_NIF

[$MAC]
      Drivername = DXMA0$
      Bindings   = ILANAT_NIF



*****************************************************
*** Banyan installation for INTERLAN AT with NDIS ***
*****************************************************

Execute PCCONFIG from workstation
Check: version of Vines must be 4.02 or higher.

From menu select: Network Card Setting
      From list select: NDIS ETHERNET
      INT = 5
      Protocol File = ILANAT_NIF
      Press F10 to save and exit to main menu

From menu select: Login Environment Setting
      From list select: NDIS ETHERNET
      Press F10 to save
      Exit PCCONFIG

Config.sys
-----------
device = c:\banyan\protman.sys /i:c:\banyan (path to protocol.ini)
device = c:\banyan\ILANAT.DOS

Protocol.ini
------------
[PROTOCOL MANAGER]
      Drivername = Protman$

[ILANAT_NIF]
      Drivername    = ILANAT$
      Iobase        = 0x300
      Maxtransmits  = 6
      Maxreceives   = 4
      Maxmulticasts = 10

[VINES_XIF]
      Drivername    = ndisban$
      Bindings      = ILANAT_NIF



***********************************************
*** Pathworks 4.X for INTERLAN AT with NDIS ***
***********************************************

Config.sys
----------
files = 50
buffers = 20
device = c:\decnet\laddrv.sys /d:4
device = c:\decnet\protman.sys /i:c:\decnet (path to protocol.ini)
device = c:\decnet\ILANAT.DOS
lastdrive=z

Protocol.ini
------------
[PROTOCOL MANAGER]
      Drivername = Protman$

[DATALINK]
      Drivername  = DLL$MAC
      LG_BUFFERS  = 16
      SM_BUFFERS  = 6
      OUTSTANDING = 32
      HEURISTICS  = 0
      Bindings    = ILANAT_NIF

[ILANAT_NIF]
      Drivername    = ILANAT$
      Iobase        = 0x300
      Maxtransmits  = 6
      Maxreceives   = 4
      Maxmulticasts = 10



***********************************************
***  Lan Manager for INTERLAN AT with NDIS  ***
***********************************************

          1.  The Lan Manager for DOS or OS/2 must be installed before
          the NDIS driver will function.  The installation procedure
          for Lan Manager is menu driven.  Among the items you will be
          prompted for during the installation include the Network
          Transport Protocol  (e.g. Netbeui), and the NDIS driver
          (e.g. ILANAT.DOS).  Another file that is installed during
          this procedure is the Protman.sys file.  This file is
          responsible for binding the transport protocol to the NDIS
          driver.

          2.  You must edit the Protocol.ini file to specify the
          following:

               a.  Specify the Transport protocol and which driver
                   to bind it to.
               b.  Specify the NDIS driver
               c.  Specify the network interface board settings.

            (e.g.)
            [protocol manager]
              drivername=protman$

            [Netbeui]
              DriveName=Netbeui$
              Bindings=ILANAT_NIF

              .
              .

            [ILANAT_NIF]
              DriverName=ILANAT$
              IOBase=0x300
              MaxTransmits=6
              MaxReceives=4
              MaxMulticasts=10

          3.  You must edit the Config.sys file to specify a path to
          Protman.sys file, the NDIS driver file, and the Transport
          protocol file.

          (e.g.)
          device=C:\path\protman.sys /I:C:\path to protocol.ini
          device=C:\path\ILANAT.DOS
          device=C:\path\Netbeui.sys ...


