QUICK INSTALLATION GUIDE<< IDE/AT<< Conner drives are low level formatted at the factory. It is only<< necessary to run SETUP, FDISK and DOS FORMAT.<< Model Hds Cyls Sec Pcomp L-Zone Type Table LED<< CP30084E 4 903 46 0 903 *UT 3 C<< Table 3 jumper settings:<< Single and Master drive = Jumper C/D<< Slave drive = no jumper<< *UT = Universal translate. Select a drive type that is close to,<< but does not exceed the megabyte capacity of the drive. The drive<< will translate to the megabyte capacity you have selected.<< LED<< C: J-5<< Pin 3 = +<< Pin 4 = -<< ST-1102A and ST1102A-32<< ===PWA=====================================================<< +....................+ /---------\<< ...................1 | O O O O |<< 1 o o 2 --------\ \ Cable Connector +-5-G-G-12+<< 3 o o 4 ------\ |<< 5 o o 6 ----\ | |<< 7 o o 8 --\ | | |<< 9 o o 10 \ | | | | 1=closed 0=open<< | | | | \-- Life-Test (Factory use)<< | | | \---- Master on (Slave off) ---- 1 1 0<< | | \------ Slave Present ------------ 0 1 0<< | \-------- Reserved<< \---------- Remote LED S M S<< i a l<< n s a<< g t v<< l e e<< e r<< Translation to use: 1024 cyl, 10 heads, 17 sectors = 89,128,960<<